Call Today (314) 329-1943 Schedule Service

Kirkwood HVAC & Plumbing Services

Plumber fixing leaking sink pipes in bathroom

Kirkwood is a growing community with an increasing number of homes and homeowners. With that growth comes a renewed demand for reliable heating, cooling, and plumbing services. Classic Aire Care is here to help. Our local HVAC professionals and licensed plumbers are well-known for the quality of their services and expertise. We have good reviews from satisfied customers in your area, so you can move forward with confidence when you schedule service.

Schedule plumbing and HVAC service for your Kirkwood home. Call (314) 329-1943 for a quote for service.

Comprehensive Air Conditioning

Classic Aire Care offers a full list of cooling services to keep your home comfortable throughout the summer. In addition to servicing traditional air conditioners, we also offer service for ductless systems. Count on us for:

Keep your cooling system running well with one call to our team. Contact us online or call (314) 329-1943 to learn about cooling services.

Schedule Your Service Today!

Top-Rated Heating

A warm, cozy home in the winter can keep your family connected and safe. We offer services for all types of heating systems, including boilers, heat pumps, and furnaces, to protect your home and family.

  • Heating repair: Get reliable heating repair service when you need it with our team, and know that we’re here for you 24/7.
  • Heating replacement: A new furnace can leave you with lower energy bills and increased home comfort, and we’ll help you find the right one.
  • Heating maintenance: Schedule a tune-up for your heating system at the start of winter, and know you’re getting efficient and reliable service throughout the season.
  • Heat pumps: Heat pumps are a reliable option for heating homes in Kirkwood, and we service all types of heat pumps.
  • Boilers: If you heat your home with a boiler, we offer repair, installation, and maintenance services so you can stay warm.

Dependable Plumbers in Kirkwood

Not only does Classic Aire Care offer a comprehensive list of HVAC services, but we also are your source for reliable plumbing help. Our team of licensed plumbers is available to help with everything from water heater replacement, including tankless water heater replacement, to general plumbing repair. We also offer backflow preventer replacement service. You can count on us to keep your plumbing operating well so you have a fully functional system.

Schedule plumbing help with Classic Aire Care by calling (314) 329-1943 or contacting us online.

Why Choose Classic Aire Care?

Classic Aire Care is no stranger to services in the Kirkwood area. We’ve been making people comfortable since 1926, and to be around for that long, we have a long list of services we provide. Our team backs everything we do with a 100% satisfaction guarantee, so you can be confident the work is done well. Our Classic Ultimate Quality Guarantee is one of the best in the business, giving you peace of mind whenever you call.

Get a free estimate by calling (314) 329-1943 or contacting our team online. We’ve been in business for over 90 years and are ready to put that expertise to work for you.

FAQs

This is called short-cycling, and it’s a sign you need professional furnace repair.

Yes, most homeowners can easily switch from a tank to a tankless water heater. All you need is the services of a professional plumber to do the installation.

Recent Jobs and Reviews in Kirkwood, MO

Kirkwood, MO at a glance

Classic Aire Care has completed 20 jobs in Kirkwood, MO in June 2026.

The most recent job was on June 23, 2026.

Classic Aire Care has completed 160 jobs in Kirkwood, MO in the last 12 months.

Job Locations and Reviews

Responded to no-cooling complaint on 10+ year old outdoor unit located at side of home. Upon arrival, system was operational but performed full diagnostic evaluation using digital manifold gauges and amp clamp to assess system performance and refrigerant charge. Measured electrical parameters, operating pressures, and temperatures at outdoor condenser unit. Inspected indoor air handler in attic space, checking refrigerant lines, condensate drain system, and electrical connections. System currently functioning but requires monitoring for intermittent operation issues reported by customer.
Responded to no-cooling complaint on 10+ year old outdoor unit located at side of home. Upon arrival, system was operational but performed full diagnostic evaluation using digital manifold gauges and amp clamp to assess system performance and refrigerant charge. Measured electrical parameters, operating pressures, and temperatures at outdoor condenser unit. Inspected indoor air handler in attic space, checking refrigerant lines, condensate drain system, and electrical connections. System currently functioning but requires monitoring for intermittent operation issues reported by customer.
Brandon F.
Brandon F. Checked in
Responded to no-cooling complaint on 10+ year old outdoor unit located at side of home. Upon arrival, system was operational but performed full diagnostic evaluation using digital manifold gauges and amp clamp to assess system performance and refrigerant charge. Measured electrical parameters, operating pressures, and temperatures at outdoor condenser unit. Inspected indoor air handler in attic space, checking refrigerant lines, condensate drain system, and electrical connections. System currently functioning but requires monitoring for intermittent operation issues reported by customer.
Kirkwood, MO 63122
Completed comprehensive cooling maintenance on two 9-year-old AC systems per customer request for early morning service. Performed standard tune-up procedures on both units including inspection of evaporator coils, condenser coils, refrigerant levels, electrical connections, and airflow components. Both systems tested and confirmed operational with no deficiencies noted; all equipment functioning within manufacturer specifications.
Completed comprehensive cooling maintenance on two 9-year-old AC systems per customer request for early morning service. Performed standard tune-up procedures on both units including inspection of evaporator coils, condenser coils, refrigerant levels, electrical connections, and airflow components. Both systems tested and confirmed operational with no deficiencies noted; all equipment functioning within manufacturer specifications.
Alex M.
Alex M. Checked in
Completed comprehensive cooling maintenance on two 9-year-old AC systems per customer request for early morning service. Performed standard tune-up procedures on both units including inspection of evaporator coils, condenser coils, refrigerant levels, electrical connections, and airflow components. Both systems tested and confirmed operational with no deficiencies noted; all equipment functioning within manufacturer specifications.
Kirkwood, MO 63122
Responded to no cooling call with reported water leak from third-floor AC unit into bathroom below. Upon arrival, located 10+ year old air handler in crawlspace and identified condensate drain line obstruction causing overflow and water damage to ceiling. Cleared blockage from drain line, tested drainage flow, and verified unit operating properly with no further leakage.
Responded to no cooling call with reported water leak from third-floor AC unit into bathroom below. Upon arrival, located 10+ year old air handler in crawlspace and identified condensate drain line obstruction causing overflow and water damage to ceiling. Cleared blockage from drain line, tested drainage flow, and verified unit operating properly with no further leakage.
Jack F.
Jack F. Checked in
Responded to no cooling call with reported water leak from third-floor AC unit into bathroom below. Upon arrival, located 10+ year old air handler in crawlspace and identified condensate drain line obstruction causing overflow and water damage to ceiling. Cleared blockage from drain line, tested drainage flow, and verified unit operating properly with no further leakage.
Kirkwood, MO 63122
# HVAC No Cool Service Call

Responded to service call for air conditioning unit not cooling with reported fan issue. Upon arrival, found unit shut off in backyard location. Performed diagnostic inspection of single AC system of unknown age. 

Accessed air handler and evaporator coil assembly for thorough examination. Observed copper evaporator coil with multiple parallel tube rows in proper configuration. Inspected condensate drain pan and float switch assembly for proper operation. Noted significant accumulation of dust, debris, and deteriorated insulation material throughout air handler cabinet and on internal components including mounting brackets, copper tubing, and heat exchanger coil fins. This heavy contamination indicated extended period without maintenance and potential airflow restriction issues.

Examined blower assembly, capacitor, and electrical connections. Multiple wire connections inspected including control wiring. Evaluated finned coil section and mechanical mounting
# HVAC No Cool Service Call

Responded to service call for air conditioning unit not cooling with reported fan issue. Upon arrival, found unit shut off in backyard location. Performed diagnostic inspection of single AC system of unknown age. 

Accessed air handler and evaporator coil assembly for thorough examination. Observed copper evaporator coil with multiple parallel tube rows in proper configuration. Inspected condensate drain pan and float switch assembly for proper operation. Noted significant accumulation of dust, debris, and deteriorated insulation material throughout air handler cabinet and on internal components including mounting brackets, copper tubing, and heat exchanger coil fins. This heavy contamination indicated extended period without maintenance and potential airflow restriction issues.

Examined blower assembly, capacitor, and electrical connections. Multiple wire connections inspected including control wiring. Evaluated finned coil section and mechanical mounting
Brandon F.
Brandon F. Checked in
# HVAC No Cool Service Call Responded to service call for air conditioning unit not cooling with reported fan issue. Upon arrival, found unit shut off in backyard location. Performed diagnostic inspection of single AC system of unknown age. Accessed air handler and evaporator coil assembly for thorough examination. Observed copper evaporator coil with multiple parallel tube rows in proper configuration. Inspected condensate drain pan and float switch assembly for proper operation. Noted significant accumulation of dust, debris, and deteriorated insulation material throughout air handler cabinet and on internal components including mounting brackets, copper tubing, and heat exchanger coil fins. This heavy contamination indicated extended period without maintenance and potential airflow restriction issues. Examined blower assembly, capacitor, and electrical connections. Multiple wire connections inspected including control wiring. Evaluated finned coil section and mechanical mounting
Kirkwood, MO 63122
Responded to no-cool call on a 2-year-old system with 2 AC units serving 3 zones. Upon arrival, diagnosed power issue preventing blower fan operation. Installed new White-Rodgers non-programmable digital thermostat and replaced second thermostat per customer request for programmable unit on main floor. Verified all electrical connections at air handler, inspected control board and capacitor wiring. Restored power to system, tested all zones for proper operation, and confirmed cooling cycle engagement across all units.
Responded to no-cool call on a 2-year-old system with 2 AC units serving 3 zones. Upon arrival, diagnosed power issue preventing blower fan operation. Installed new White-Rodgers non-programmable digital thermostat and replaced second thermostat per customer request for programmable unit on main floor. Verified all electrical connections at air handler, inspected control board and capacitor wiring. Restored power to system, tested all zones for proper operation, and confirmed cooling cycle engagement across all units.
Mitchell L.
Mitchell L. Checked in
Responded to no-cool call on a 2-year-old system with 2 AC units serving 3 zones. Upon arrival, diagnosed power issue preventing blower fan operation. Installed new White-Rodgers non-programmable digital thermostat and replaced second thermostat per customer request for programmable unit on main floor. Verified all electrical connections at air handler, inspected control board and capacitor wiring. Restored power to system, tested all zones for proper operation, and confirmed cooling cycle engagement across all units.
Kirkwood, MO 63122
Installed a 50-gallon tall gas water heater in basement utility area, completing all copper piping connections to existing overhead plumbing system. Coordinated afternoon arrival for equipment pickup and verified City of Kirkwood permit requirements, which did not require plumbing ID sticker for this installation. All connections tested and system operational upon completion.
Installed a 50-gallon tall gas water heater in basement utility area, completing all copper piping connections to existing overhead plumbing system. Coordinated afternoon arrival for equipment pickup and verified City of Kirkwood permit requirements, which did not require plumbing ID sticker for this installation. All connections tested and system operational upon completion.
Jon W.
Jon W. Checked in
Installed a 50-gallon tall gas water heater in basement utility area, completing all copper piping connections to existing overhead plumbing system. Coordinated afternoon arrival for equipment pickup and verified City of Kirkwood permit requirements, which did not require plumbing ID sticker for this installation. All connections tested and system operational upon completion.
Kirkwood, MO 63122
Completed electrical repairs addressing multiple fixture and switch issues throughout the property. Replaced non-functioning pull chain switch on garage loft light fixture, installed new light bulbs in basement fixtures, diagnosed and replaced faulty bathroom fan switch while verifying light switch operation remained intact, and replaced defective switch in garage to restore proper functionality. All fixtures tested and confirmed operational upon completion.
Completed electrical repairs addressing multiple fixture and switch issues throughout the property. Replaced non-functioning pull chain switch on garage loft light fixture, installed new light bulbs in basement fixtures, diagnosed and replaced faulty bathroom fan switch while verifying light switch operation remained intact, and replaced defective switch in garage to restore proper functionality. All fixtures tested and confirmed operational upon completion.
Kyle H.
Kyle H. Checked in
Completed electrical repairs addressing multiple fixture and switch issues throughout the property. Replaced non-functioning pull chain switch on garage loft light fixture, installed new light bulbs in basement fixtures, diagnosed and replaced faulty bathroom fan switch while verifying light switch operation remained intact, and replaced defective switch in garage to restore proper functionality. All fixtures tested and confirmed operational upon completion.
Kirkwood, MO 63122
Completed installation of 50-gallon tall electric water heater in basement utility area. Unit was set up and prepared for delivery with all necessary plumbing connections, including copper piping, expansion tank, and flexible connectors properly installed per manufacturer specifications and local code requirements.
Completed installation of 50-gallon tall electric water heater in basement utility area. Unit was set up and prepared for delivery with all necessary plumbing connections, including copper piping, expansion tank, and flexible connectors properly installed per manufacturer specifications and local code requirements.
James W.
James W. Checked in
Completed installation of 50-gallon tall electric water heater in basement utility area. Unit was set up and prepared for delivery with all necessary plumbing connections, including copper piping, expansion tank, and flexible connectors properly installed per manufacturer specifications and local code requirements.
Kirkwood, MO 63122
Performed comprehensive cooling system tune-up on a single unit located in side yard. Upon inspection, discovered significant debris accumulation on evaporator coil and blower wheel assembly, restricting airflow and reducing system efficiency. Cleaned blower wheel to remove dust buildup and thoroughly cleaned evaporator coil to eliminate dense fiber and lint accumulation that had collected on coil surfaces. Documented pre-service conditions with photographs showing extent of contamination on both components. Restored proper airflow through system, improving cooling performance and operational efficiency.
Performed comprehensive cooling system tune-up on a single unit located in side yard. Upon inspection, discovered significant debris accumulation on evaporator coil and blower wheel assembly, restricting airflow and reducing system efficiency. Cleaned blower wheel to remove dust buildup and thoroughly cleaned evaporator coil to eliminate dense fiber and lint accumulation that had collected on coil surfaces. Documented pre-service conditions with photographs showing extent of contamination on both components. Restored proper airflow through system, improving cooling performance and operational efficiency.
Matt S.
Matt S. Checked in
Performed comprehensive cooling system tune-up on a single unit located in side yard. Upon inspection, discovered significant debris accumulation on evaporator coil and blower wheel assembly, restricting airflow and reducing system efficiency. Cleaned blower wheel to remove dust buildup and thoroughly cleaned evaporator coil to eliminate dense fiber and lint accumulation that had collected on coil surfaces. Documented pre-service conditions with photographs showing extent of contamination on both components. Restored proper airflow through system, improving cooling performance and operational efficiency.
Kirkwood, MO 63122
Completed comprehensive cooling system tune-up on 2-year-old Lennox unit per manufacturer specifications. Performed visual inspection of condenser coil assembly, confirming clean fins with no debris accumulation or corrosion present. Inspected control board and electrical connections, verifying all wiring terminals secure and circuit board components functioning properly. Unit operating within normal parameters with no issues identified during service.
Completed comprehensive cooling system tune-up on 2-year-old Lennox unit per manufacturer specifications. Performed visual inspection of condenser coil assembly, confirming clean fins with no debris accumulation or corrosion present. Inspected control board and electrical connections, verifying all wiring terminals secure and circuit board components functioning properly. Unit operating within normal parameters with no issues identified during service.
Brad S.
Brad S. Checked in
Completed comprehensive cooling system tune-up on 2-year-old Lennox unit per manufacturer specifications. Performed visual inspection of condenser coil assembly, confirming clean fins with no debris accumulation or corrosion present. Inspected control board and electrical connections, verifying all wiring terminals secure and circuit board components functioning properly. Unit operating within normal parameters with no issues identified during service.
Kirkwood, MO 63122
Responded to service call for non-functioning light fixture and intermittent ceiling fan light issue in bedroom. Troubleshot pindon light that remained inoperative after bulb replacement, identified electrical fault, and restored functionality. Diagnosed and repaired ceiling fan causing intermittent light operation in bedroom, ensuring reliable operation of both lighting circuits.
Responded to service call for non-functioning light fixture and intermittent ceiling fan light issue in bedroom. Troubleshot pindon light that remained inoperative after bulb replacement, identified electrical fault, and restored functionality. Diagnosed and repaired ceiling fan causing intermittent light operation in bedroom, ensuring reliable operation of both lighting circuits.
Kyle H.
Kyle H. Checked in
Responded to service call for non-functioning light fixture and intermittent ceiling fan light issue in bedroom. Troubleshot pindon light that remained inoperative after bulb replacement, identified electrical fault, and restored functionality. Diagnosed and repaired ceiling fan causing intermittent light operation in bedroom, ensuring reliable operation of both lighting circuits.
Kirkwood, MO 63122
Responded to a basement drain backup with sewage overflow. Upon arrival, located the main sewer cleanout access point in the backyard and removed the cap to assess the blockage. Utilized a power auger with flexible cable to clear the obstruction in the main sewer line. Successfully restored proper drainage flow and verified system functionality. Replaced cleanout cap and secured all access points upon completion.
Responded to a basement drain backup with sewage overflow. Upon arrival, located the main sewer cleanout access point in the backyard and removed the cap to assess the blockage. Utilized a power auger with flexible cable to clear the obstruction in the main sewer line. Successfully restored proper drainage flow and verified system functionality. Replaced cleanout cap and secured all access points upon completion.
La'Quan T.
La'Quan T. Checked in
Responded to a basement drain backup with sewage overflow. Upon arrival, located the main sewer cleanout access point in the backyard and removed the cap to assess the blockage. Utilized a power auger with flexible cable to clear the obstruction in the main sewer line. Successfully restored proper drainage flow and verified system functionality. Replaced cleanout cap and secured all access points upon completion.
Kirkwood, MO 63122
Kirkwood, MO - Responded to a no-power condition affecting backyard light fixtures. Upon inspection, accessed the main electrical panel and identified a tripped circuit breaker serving the exterior lighting circuit. Reset the breaker and verified power restoration to all affected fixtures in the backyard area.
David Y.
David Y. Checked in
Responded to a no-power condition affecting backyard light fixtures. Upon inspection, accessed the main electrical panel and identified a tripped circuit breaker serving the exterior lighting circuit. Reset the breaker and verified power restoration to all affected fixtures in the backyard area.
Kirkwood, MO 63122
Replaced defective thermal expansion valve (TXV) on system S/N 1522G74733 to restore cooling operation. Unit was experiencing no-cool condition due to failed TXV. Recovered refrigerant, removed old valve assembly, installed new TXV with proper torque specifications on brass fittings, evacuated system, and recharged to manufacturer specifications. Verified proper system operation with temperature differential and pressures within normal range. Retained failed part per protocol.
Replaced defective thermal expansion valve (TXV) on system S/N 1522G74733 to restore cooling operation. Unit was experiencing no-cool condition due to failed TXV. Recovered refrigerant, removed old valve assembly, installed new TXV with proper torque specifications on brass fittings, evacuated system, and recharged to manufacturer specifications. Verified proper system operation with temperature differential and pressures within normal range. Retained failed part per protocol.
Matt S.
Matt S. Checked in
Replaced defective thermal expansion valve (TXV) on system S/N 1522G74733 to restore cooling operation. Unit was experiencing no-cool condition due to failed TXV. Recovered refrigerant, removed old valve assembly, installed new TXV with proper torque specifications on brass fittings, evacuated system, and recharged to manufacturer specifications. Verified proper system operation with temperature differential and pressures within normal range. Retained failed part per protocol.
Kirkwood, MO 63122
Responded to service call for 18-year-old Comfortmaker air conditioning system experiencing intermittent operation and shutting off on its own, affecting entire home cooling. Performed comprehensive U10 cooling maintenance service as part of annual preventative maintenance program. Conducted thorough inspection of outdoor condensing unit, verifying proper airflow through condenser coil fins and checking overall component condition. Inspected and assessed indoor blower wheel assembly, noting dust accumulation on blower housing and wheel blades. Cleaned blower components to restore optimal airflow and system efficiency. Verified proper system operation following maintenance procedures. Unit returned to normal operation with improved performance after cleaning and inspection protocol completed.
Responded to service call for 18-year-old Comfortmaker air conditioning system experiencing intermittent operation and shutting off on its own, affecting entire home cooling. Performed comprehensive U10 cooling maintenance service as part of annual preventative maintenance program. Conducted thorough inspection of outdoor condensing unit, verifying proper airflow through condenser coil fins and checking overall component condition. Inspected and assessed indoor blower wheel assembly, noting dust accumulation on blower housing and wheel blades. Cleaned blower components to restore optimal airflow and system efficiency. Verified proper system operation following maintenance procedures. Unit returned to normal operation with improved performance after cleaning and inspection protocol completed.
Brandon F.
Brandon F. Checked in
Responded to service call for 18-year-old Comfortmaker air conditioning system experiencing intermittent operation and shutting off on its own, affecting entire home cooling. Performed comprehensive U10 cooling maintenance service as part of annual preventative maintenance program. Conducted thorough inspection of outdoor condensing unit, verifying proper airflow through condenser coil fins and checking overall component condition. Inspected and assessed indoor blower wheel assembly, noting dust accumulation on blower housing and wheel blades. Cleaned blower components to restore optimal airflow and system efficiency. Verified proper system operation following maintenance procedures. Unit returned to normal operation with improved performance after cleaning and inspection protocol completed.
Kirkwood, MO 63122
Kirkwood, MO - Responded to no cooling complaint on three-year-old Lennox system affecting entire residence currently under construction. Upon arrival, performed diagnostic testing of unit and measured supply air temperature at 59°F, indicating inadequate cooling performance. Inspected indoor air handler, ductwork, and refrigerant lines in mechanical space to identify root cause of cooling failure and restore proper system operation.
Matt S.
Matt S. Checked in
Responded to no cooling complaint on three-year-old Lennox system affecting entire residence currently under construction. Upon arrival, performed diagnostic testing of unit and measured supply air temperature at 59°F, indicating inadequate cooling performance. Inspected indoor air handler, ductwork, and refrigerant lines in mechanical space to identify root cause of cooling failure and restore proper system operation.
Kirkwood, MO 63122
Kirkwood, MO - Responded to no cooling complaint on 9-year-old Trane (Ameristar) system with thermostat set at 79°F but house temperature remaining at 83°F. Upon inspection, discovered severely damaged low-voltage wiring outside the unit with deteriorated insulation and exposed copper conductors. Replaced damaged wiring, restored proper electrical connections, tested system operation, and verified cooling cycle restored to normal functionality.
Eric C.
Eric C. Checked in
Responded to no cooling complaint on 9-year-old Trane (Ameristar) system with thermostat set at 79°F but house temperature remaining at 83°F. Upon inspection, discovered severely damaged low-voltage wiring outside the unit with deteriorated insulation and exposed copper conductors. Replaced damaged wiring, restored proper electrical connections, tested system operation, and verified cooling cycle restored to normal functionality.
Kirkwood, MO 63122
Kirkwood, MO - Responded to no-cooling call on residential air conditioning system over 10 years old. Upon arrival, found condenser fan motor inoperative with visible signs of wear, dirt accumulation, and environmental exposure on motor housing and mounting components. Diagnosed failed condenser fan motor preventing proper heat rejection from outdoor unit, confirmed unit was safely turned off per prior instructions to prevent compressor damage from inadequate airflow.
Chris R.
Chris R. Checked in
Responded to no-cooling call on residential air conditioning system over 10 years old. Upon arrival, found condenser fan motor inoperative with visible signs of wear, dirt accumulation, and environmental exposure on motor housing and mounting components. Diagnosed failed condenser fan motor preventing proper heat rejection from outdoor unit, confirmed unit was safely turned off per prior instructions to prevent compressor damage from inadequate airflow.
Kirkwood, MO 63122
Completed preventive maintenance tune-up on two cooling systems. Performed comprehensive inspections including electrical measurements with digital clamp meter to verify proper amperage draw and system performance. Inspected air filtration components, noting accumulated dust and debris on mesh filter requiring attention. Both systems operational and running within normal parameters upon completion of maintenance procedures.
Completed preventive maintenance tune-up on two cooling systems. Performed comprehensive inspections including electrical measurements with digital clamp meter to verify proper amperage draw and system performance. Inspected air filtration components, noting accumulated dust and debris on mesh filter requiring attention. Both systems operational and running within normal parameters upon completion of maintenance procedures.
Brandon F.
Brandon F. Checked in
Completed preventive maintenance tune-up on two cooling systems. Performed comprehensive inspections including electrical measurements with digital clamp meter to verify proper amperage draw and system performance. Inspected air filtration components, noting accumulated dust and debris on mesh filter requiring attention. Both systems operational and running within normal parameters upon completion of maintenance procedures.
Kirkwood, MO 63122
Responded to no cooling call with reported intermittent fan operation and unusual noise. Upon inspection, found severely restricted airflow due to heavily clogged air filter with significant dust and debris accumulation. Replaced dirty filter and verified proper system operation. Unit tested successfully with normal cooling cycle, consistent fan operation, and no abnormal sounds. System restored to proper working condition.
Responded to no cooling call with reported intermittent fan operation and unusual noise. Upon inspection, found severely restricted airflow due to heavily clogged air filter with significant dust and debris accumulation. Replaced dirty filter and verified proper system operation. Unit tested successfully with normal cooling cycle, consistent fan operation, and no abnormal sounds. System restored to proper working condition.
Griffin F.
Griffin F. Checked in
Responded to no cooling call with reported intermittent fan operation and unusual noise. Upon inspection, found severely restricted airflow due to heavily clogged air filter with significant dust and debris accumulation. Replaced dirty filter and verified proper system operation. Unit tested successfully with normal cooling cycle, consistent fan operation, and no abnormal sounds. System restored to proper working condition.
Kirkwood, MO 63122

Get An Instant Online Quote

Answer 4 easy questions and get a free onscreen quote on a new furnace and A/C or water heater

request quote
Review Image
our reviews

See What Your Neighbors Are Saying

Top notch install quality. While my ac wasn’t that old, I opted for a higher efficiency heat pump system and replace my worn-out older furnace! The difference in my home is night and day difference, can’t wait to see what the bills do.

Sean K.

Sean K.

Great customer service! Called for an emergency with my furnace after hours (in the middle of winter), a mishap happened with their system. The manager Joe called me immediately in the morning, discounted my service and got Jack out in an hour. Diagnosed and fixed same…

Ebony K.

Ebony K.

I have my furnace and air conditioning system on a maintenance agreement with Classic Aire Care to be checked twice a year. They have been doing this since the system was installed eight years ago. They do excellent work and technicians are quality people. I would…

Gerald B.

Gerald B.

We enjoy the promptness and professionalism of every person we have met, encountered or had enter our home. They are very clean, neat and down-to-business kind of employees. Couldn't ask for more.

Cindy K.

Cindy K.

The Professionalism of this company as well our service technician Greg was more than just five-star rating. He took the time explained everything that he did and now my unit is running at tiptop shape.

Charles P.

Charles P.

What To Expect

Discover the Difference

100% Satisfaction Guaranteed

Over 100 Vans on The Road, Ready to Offer Same-Day Service

Over 3,000 5-Star Reviews

Free Estimates

Highly Trained Techs With Over 35 Years Of Experience

Commitment to Community

100% Satisfaction Guaranteed

Over 100 Vans on The Road, Ready to Offer Same-Day Service

Over 3,000 5-Star Reviews

Free Estimates

Highly Trained Techs With Over 35 Years Of Experience

Commitment to Community

Truck Image
Join the Classic Aire Care Membership Program

Save on Service & Enjoy Peace of Mind

  • Priority customer status
  • Discounts on repair services
  • Comprehensive maintenance & tune-ups
  • No overtime charges
  • Extended equipment life

Â